Supplied Solutions

Moxa - TCC-82 Port-powered RS-232 isolator

TCC-82



 

Features
Specifications
Ordering Information

Features and Benefits

  • 4 channels of 4 KV RMS isolation for 1 minute
  • External power source supported but not required
  • 15 KV serial ESD protection
  • Automatic baudrate detection
  • Compact size

Introduction

The Moxa TCC-82 provides full electrical isolation for bi-directional serial communication between two RS-232 devices in a compact, industrial grade package. Both sides of an RS-232 connection are isolated optically to provide perfect protection against lightning surges, accidental high voltage shorts, and ground loops. The built-in, wide range isolators are tested to ensure that they can withstand more than 4 KV rms input to output for 1 minute. This means that the TCC-82 not only meets the requirements of general serial data communications, but also the high standards required by industrial automation and medical applications. The TCC-82 protects the TxD and RxD data lines, and also protects the RTS and CTS handshake lines for a total of 4 isolated channels to provide complete protection of your RS-232 applications.

External Power Source Not Required

The TCC-82 supports port-powered operation, which means that it can obtain power directly from the attached serial devices. Power is obtained from the RS-232 TxD, RTS, or DTR lines, regardless of whether the signal is high or low, eliminating the need for an external power supply. However, external power can be used if handshake lines are not available, if the serial cable is too long, or if the serial device is a low powered device. For external power, the TCC-82 can use a 5 to 12 VDC adaptor or a USB power cord. Note that both sides of the connection are powered independently, so if necessary, one side can rely on port power and the other on an external power source. When installing the TCC-82, we recommend that you connect all output signals. The TCC-82 obtains power from these signals even if they are not used by your system. Care should be taken when choosing the external power supply if your application requires the full 4 KV of isolation. Most commercial power supplies provide only 1500 VAC isolation between the primary and secondary windings. If you are using external power for both sides of the TCC-82, make sure that separate power sources are used, each with sufficient isolation protection.

• Serial Communication
Connector(s) DB9 male and DB9 female
RS-232 Signals TxD, RxD, RTS, CTS
(Loop-back wiring: DTR to DSR and DCD)
ESD Protection 15 KV for all signals
Optical Isolation Protection 4 KV for 1 minute
Baudrate 50 bps to 921.6 Kbps


• Physical Characteristics
Enclosure ABS
Weight 60 ± 5 g
Dimensions 42 x 80 x 23.6 mm (1.65 x 3.15 x 0.93 in)


• Environmental Limits
Operating Temperature 0 to 60°C (32 to 140°F)
Operating Humidity 5 to 95% RH
Storage Temperature -20 to 75°C (-14 to 167°F)


• Power Requirements
Source of Input Power RS-232 port (TxD signal) or power input jack
Input Voltage 5 to 12 VDC
Power Consumption 20 mA @ 5 V


• Regulatory Approvals
CE Class B
FCC Class B


• Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty


Ordering Info Model No. Description
Click here to order

TCC-82

Port-powered RS-232 isolator with 4 KV isolation and 15 KV serial ESD protection


Power Adaptors and Cords
Ordering Info Model No. Description
Click here to order

P/N: 1117000025200

230 VAC, 50 Hz,Euro plug
Click here to order

P/N: 1117000025400

230 VAC, 50 Hz,UK plug
Click here to order

P/N: 1117000022700

100 to 240 VAC, 50/60 Hz,Japan plug
Click here to order

P/N: 1117000025300

120 VAC, 60 Hz,US plug
Click here to order

P/N: 1117000025500

230 VAC, 50 Hz,Euro plug


Connection Cables
Ordering Info Model No. Description
Click here to order

CBL-USBAP-50

USB Power Cord (50 cm)
Click here to order

CBL-F9M9-20

DB9 male to DB9 female RS-232 cable (20 cm)

logo
mtsclogo

Phone:1300 669 228 | Email: salessupport@suppliedsolutions.com.au
Copyright © Supplied Solutions 2008.